

Remember to select these new parameters in the graph or statistics windows!įlowJo can transform the display of compensated data so that populations no longer are displayed squished against the axis. The parameter name is bracketed with "": e.g., when FITC and PE are compensated against each other, two new parameters named " " and " " will be created. Compensated samples have new parameters added to their list: for each fluorescence channel to be compensated, a new parameter is created. Each new compensation matrix is given its own color for easy recognition of which matrix has been applied to which sample(s). You can remove a compensation matrix by selecting Platform -> Compensate Sample -> Remove Compensation.Īny sample that has been compensated is marked with a blue bar next to the sample name in the workspace window. Note that a compensation matrix is generally valid only for samples collected during a single collection run! However, you can also edit the matrix using the "Edit/Save Matrix" option. To use that matrix in other workspaces, save the matrix to a file ("Edit/Save Matrix") and load the matrix file into the new workspace ("Load matrix"). You may subsequently apply that compensation matrix to other samples in the same workspace by selecting it from the menu.

Once you have defined a compensation matrix, it is saved with the workspace.

You may also view an example of the entire compensation process, as a tutorial. This is where the Compensation Wizard will save time and effort. If you need to generate another compensation matrix for other samples in the experiment, you can just repeat steps 2 through 4 as needed.
#HOW TO COMPENSATE IN FLOWJO 10 IN WINDOW HOW TO#
The remainder of the documentation below is NOT meant to teach you about compensation, simply how to use FlowJo to perform that function.įlowJo computes the compensation matrix on control samples much the way you would manually set the compensation. Also, there may be cases where the instrument is not capable of compensating between certain channels (for instance, to correct for the spillover between fluorescein and Cy5PE).įor a description of why compensation is necessary, the underlying concepts behind compensation, and some of the pitfalls of improper compensation, see the " Compensation: A perspective" by Mario Roederer (you need to be connected to a network to view this site). This may be necessary in cases where the compensation was inappropriately set during sample collection (although if the sample was over-compensated, then there is no recourse). FlowJo gives you the ability to compensate your data.
